VLT® AQUA Drive FC 202

Rp. 1.500.000,00




Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, the VLT® AQUA Drive provides the lowest overall cost of ownership as a result of energy savings and easy maintenance.

 

Features and benefits

Power and voltage range
200-240 V.....0.25 kW - 45 kW
380-480 V.....0.37 kW - 1000 kW
525-600 V.....0.75 kW - 90 kW
525-690 V....11 kW - 1.4 MW

Three phase
3*200-240V… 0.25 - 45 kW
3*380-480V… 0.37 - 1000 kW
3*525-600V… 0.75 - 90 kW
3*525-690V… 11 - 1.4 MW

Single phase
1*200-240V 1.1 - 22kW
1*380-480V 7.5 - 37kW

Enclosures
IP20/chassis, IP21/NEMA 1, IP55/NEMA 12 and IP66/NEMA 4X

Dedicated water features Auto tuning of the PI controllers
With auto tuning of the PI controllers, the drive monitors how the system reacts on corrections made by the drive - and learns from it, so that precise and stable operation is achieved quickly.

Automatic Energy Optimization

The standard feature AEO provides optimized motor magnetization at all speeds and loads. This increases energy efficiency by 5-15% for partial loads.

 

Energy monitoring  

The VLT AQUA Drive provides a complete range of energy consumption information, which helps identify low-efficiency components in the system.

 

PM motor support

Support for any non salient permanent magnet motor up to 22 kW for better system efficiency.

 

Pipe Fill Mode
Enables controlled (closed loop) filling of pipes. Prevents water hammering and bursting water pipes, or blowing off sprinkler heads.

End of Pump Curve detects breaks and leakage
The feature detects breaks and leakage. End of curve triggers an alarm and shuts off the pump, or performs another user defined action.

Dry Pump Protection lowers maintenance costs
The VLT AQUA Drive constantly evaluates the condition of the pump based on internal frequency/power measurements.

Deragging

Can be used as a proactive or reactive feature of the AQUA Drive for wastewater applications to prevent clogging of pumps. Deragging helps to avoid downtime and reduces maintenance cost.

 

Cascade controller solutions
The built-in standard cascade controller controls up to three pumps with a fixed lead pump. The optional Extended and Advanced Cascade Controller makes it possible to extend the number of pumps and ensure smooth staging/de-staging, also in mixed pump and variable speed pump applications.

Motor Alternation
This built-in logic controls alternation between two pumps in duty/stand-by applications. Motion of the stand-by pump prevents the pump from sticking. An internal timer assures equal usage of the pumps.

Flow compensation
The flow compensation feature reduces the pressure set point according to the flow, which saves energy.

Initial/Final Ramp
The initial ramp provides fast acceleration of pumps to minimum speed, from where the normal ramp takes over. This prevents damage on thrust and bearings.

Check Valve Ramp

The Check Valve Ramp of the VLT AQUA Drive prevents water hammering as check valves close smoothly when the pump stops.

 

Quick Menu

The user-friendly Quick Menu, and its submenus of the VLT AQUA Drive, saves time during drive configuration. The submenu "Water and Pumps" provides direct access to application specific features.

Safety
The VLT AQUA Drive can optionally be delivered with the safe torque off (safe stop) functionality suitable for category 3, performance level d according to EN 13849-1 and SIL 2 according to IEC 62061/IEC 61508. This feature prevents the drive from starting unintended.

 

 

Accessories

A wide selection of accessories is available for the VLT AQUA Drive to suit your needs. For further details see the Operation Instructions.

Options
Options for bus communication, user programs, etc., are delivered ready for plug and play.

Display options
Local Control Panel LCP (graphical and numerical)
Cable for LCP, 3 m [9,8 ft.]
Remote-mounting kit for Local Control Panel (LCP)

Blind cover

Fieldbus options

VLT PROFIBUS DP/V1 MCA 101
VLT DeviceNet MCA 104

VLT PROFINET MCA 120
VLT EtherNet IP MCA 121

VLT Modbus TCP MCA 122

I/O options
VLT Extended I/O MCB 101

VLT Relay Card MCB 105)
VLT Extended Cascade Controller MCO 101
VLT Advanced Cascade Controller MCO 102
VLT Analog I/O MCB 109

 

VLT PTC Thermistor Card MCB 112
VLT Sensor Input MCB 114

Filters 

VLT Sine-wave Filter MCC 101

VLT dU/dt Filter MCC 102

VLT Common Mode Filter MCC 105

PC software tools

VLT Motion Control Tool MCT 10 for commissioning and servicing

VLT Motion Control Tool MCT 31 for calculating harmonic distortion

 


Other accessories

VLT 24V external supply MCB 107
IP21/NEMA1 Kit

Kit for panel through mount
USB connection cable to PC

 

 

P.T. APSINDO GANANCIA PERKASA

Jl. Kelapa Gading Selatan BH 10/27
Gading Serpong, Tangerang 15810
Indonesia
Phone  : +62-21-547 0968
Fax        : +62-21-5420 4738
E-mail    : apsindo@cbn.net.id

 



 

 
Home | About Us | Product | Gallery |Contact Us
Copyright apsindoganancia.com, 2012 - 2024. All Rights Reserved Powered by